Product Brief
SNCR Denitrification Kit
The SNCR denitrification kit is mainly used for waste incinerator denitrification process, namely SNCR. According to this process, at the high temperature (800°C~1000°C), Nox is reduced to N₂ by reductant such as ammonia or urea, which does not need catalyst. The incinerator temperature allows the reduction reaction completed in the waste incinerator. The system has the advantages of low investment, simplicity, convenience and high efficiency. Under this system, NOX in MSWI flue gas can be reduced from 400mg/Nm³ to 200 mg/Nm³ below. The denitrification efficiency is more than 50%.
- Specification & Series:This equipment is suitable for the denitrification treatment of flue gas from MSWI waste incinerators in large, medium and small towns in China. According to the project size, the process equipment is calculated and is non-standard equipment.
- Processing Capacity:It is suitable for waste incinerators of the single line waste throughput ≥ 300t/d
- Application Fields:Location: indoor ;
Plant voltage level: AC: 380V\220V,50H;
Reductant: urea or ammonia.
SERVICE CALL+86 13521339794
Price Inquiry
Online Remarks
enfi.cemsa@gmail.com
Advantages & Features
- The system and equipment selection can be calculated according to the combustion condition of the boiler in different projects. On this basis, the fluid numerical modeling computer simulation can guide the equipment design, selection and non-standard customization;
- It can optimize the system and the process design, and reduce system costs. It has strong controllability, high-quality equipment, and long service life.
Working Principle
Selective Non-Catalytic Reduction means that at the flue gas temperature of 850~1100°C, existing with O₂, the denitration agent such as NH₃ or (CO(NH₂)₂) is directly added to the furnace. 8~25% NH₃ is added to the furnace under 0.3-0.7 pressure to reduce NOx to nitrogen and water at high temperature. The denitration efficiency is more than 50%. The process does not need the catalyst, which can avoid catalyst blockage or poisoning.
Technical Parameters
Technological parameters | |
---|---|
Reaction temperature | 850℃ 1000℃ |
Reductant concentration | 5-8% |
NOX removal efficiency | >50% |
The Application Achievements